RÉFÉRENCES
- Al-Rafee, M.A., The epidemiology of edentulism and the associated factors: A literature Review. J Family Med Prim Care, 2020. 9(4): 1841-1843.
- Polzer, I., et al., Edentulism as part of the general health problems of elderly adults. International Dental Journal, 2010. 60(3): 143-155.
- Gupta, A., et al., Rehabilitation of Edentulism and Mortality: A Systematic Review. J Prosthodont, 2019. 28(5): 526-535.
- Owen, P.C., Appropriatech: prosthodontics for the many, not just for the few. Int J Prosthodont, 2004. 17(3): 261-2.
- Carlsson, G.E. and R. Omar, The future of complete dentures in oral rehabilitation. A critical review. Journal of Oral Rehabilitation, 2010. 37(2): 143-156.
- Manzon, L., I. Vozza, and O. Poli, Bite Force in Elderly with Full Natural Dentition and Different Rehabilitation Prosthesis. International Journal of Environmental Research and Public Health, 2021. 18(4): 1424.
- Sharma, A.J., R. Nagrath, and M. Lahori, A comparative evaluation of chewing efficiency, masticatory bite force, and patient satisfaction between conventional denture and implantsupported mandibular overdenture: An in vivo study. J Indian Prosthodont Soc, 2017. 17(4): 361-372.
- Boven, G.C., et al., Improving masticatory performance, bite force, nutritional state and patient’s satisfaction with implant overdentures: a systematic review of the literature. Journal of Oral Rehabilitation, 2015. 42(3): 220-233.
- Watson, R.M., et al., Prosthodontic treatment, patient response, and the need for maintenance of complete implant-supported overdentures: An appraisal of 5 years of prospective study. International Journal of Prosthodontics, 1997. 10(4): 345-354.
- Asawa, N., et al., Angulated implants: an alternative to bone augmentation and sinus lift procedure: systematic review. J Clin Diagn Res, 2015. 9(3): ZE10-3.
- Rosenstein, J. and H. Dym, Zygomatic Implants: A Solution for the Atrophic Maxilla. Dent Clin North Am, 2020. 64(2): 401-409.
- Mommaerts, M.Y., Evolutionary steps in the design and biofunctionalization of the additively manufactured sub-periosteal jaw implant ‘AMSJI’ for the maxilla. Int J Oral Maxillofac Surg, 2019. 48(1): 108-114.
- Ridell, A., K. Grondahl, and L. Sennerby, Placement of Branemark implants in the maxillary tuber region: anatomical considerations, surgical technique and long-term results. Clin Oral Implants Res, 2009. 20(1): 94-8.
- González-Valls, G., et al., Narrow Diameter Dental Implants as an Alternative Treatment for Atrophic Alveolar Ridges. Systematic Review and MetaAnalysis. Materials (Basel), 2021. 14(12).
- Yu, X., et al., A meta-analysis indicating extra-short implants (≤ 6 mm) as an alternative to longer implants (≥ 8 mm) with bone augmentation. Sci Rep, 2021. 11(1): 8152.
- Schiegnitz, E. and B. Al-Nawas, Narrow-diameter implants: A systematic review and meta-analysis. Clin Oral Implants Res, 2018. 29 Suppl 16: 21-40.
- Pommer, B., et al., Extra-short (< 7 mm) and extra-narrow diameter (< 3.5 mm) implants: a meta-analytic literature review. Eur J Oral Implantol, 2018. 11 Suppl 1: S137-S146.
- Cochran, D.L., The evidence for immediate loading of implants. J Evid Based Dent Pract, 2006. 6(2): 155-63.
- Salman, A., et al., Immediate versus delayed loading of mandibular implant-retained overdentures: A 60-month follow-up of a randomized clinical trial. Journal of Clinical Periodontology, 2019. 46(8): 863-871.
- El Ghoul, W. and J.J. Chidiac, Prosthetic Requirements for Immediate Implant Loading: A Review. Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry, 2012. 21(2): 141-154.
- Degidi, M., et al., Syncrystallization: a technique for temporization of immediately loaded implants with metal-reinforced acrylic resin restorations. Clin Implant Dent Relat Res, 2006. 8(3): 123-34.
- Siadat, H., M. Alikhasi, and E. Beyabanaki, Interim Prosthesis Options for Dental Implants. J Prosthodont, 2017. 26(4): p. 331-338.
- Cawood, J.I. and R.A. Howell, A classification of the edentulous jaws. International Journal of Oral and Maxillofacial Surgery, 1988. 17(4): 232-236.
- Van Doorne, L., et al., Three-Dimensional Radiographic Outcome of Free-Handed Flaplessly Placed Mini Dental Implants in Edentulous Maxillae after 2-Years Function. J Clin Med, 2020. 9(7).
- Carpentieri, J., G. Greenstein, and J. Cavallaro, Hierarchy of restorative space required for different types of dental implant prostheses. J Am Dent Assoc, 2019. 150(8): 695-706.
- Van Doorne, L., et al., Flaplessly placed 2.4-mm mini-implants for maxillary overdentures: a prospective multicentre clinical cohort study. Int J Oral Maxillofac Surg, 2019.
- Mommaerts, M.Y., Additively manufactured sub-periosteal jaw implants. Int J Oral Maxillofac Surg, 2017. 46(7): 938-940.
- Malo, P., et al., Immediate function dental implants inserted with less than 30N.cm of torque in fullarch maxillary rehabilitations using the All-on-4 concept: retrospective study. Int J Oral Maxillofac Surg, 2018. 47(8): 1079-1085.
- Stawarczyk, B., et al., Three-unit reinforced polyetheretherketone composite FDPs: influence of fabrication method on load-bearing capacity and failure types. Dent Mater J, 2015. 34(1): 7-12.
- Zoidis, P., I. Papathanasiou, and G. Polyzois, The Use of a Modified Poly-Ether-Ether-Ketone (PEEK) as an Alternative Framework Material for Removable Dental Prostheses. A Clinical Report. J Prosthodont, 2016. 25(7): 580-584.
- Jin, H.Y., et al., Comparative evaluation of BioHPP and titanium as a framework veneered with composite resin for implant-supported fixed dental prostheses. J Prosthet Dent, 2019. 122(4): 383-388.
- Monje, A., et al., Do implant length and width matter for short dental implants (<10 mm)? A meta-analysis of prospective studies. J Periodontol, 2013. 84(12): 1783-91.
- Katzer, A., et al., Polyetheretherketone-cytotoxicity and mutagenicity in vitro. Biomaterials, 2002. 23(8): 1749-1759.
- Kuoppala, R., R. Näpänkangas, and A. Raustia, Outcome of implant-supported overdenture treatment–a survey of 58 patients. Gerodontology, 2012. 29(2): e577-84.
- Park, C., et al., Use of polyaryletherketone (PAEK) based polymer for implant-supported telescopic overdenture: A case report. J Adv Prosthodont, 2017. 9(1): 74-76.
- Güzelce, S.E., Biomechanical comparison of different framework materials in mandibular overdenture prosthesis supported with implants of different sizes: a finite element analysis. BMC Oral Health, 2023. 23(1): 450.
- Gama, L.T., et al., Clinical performance of polymer frameworks in dental prostheses: A systematic review. Journal of Prosthetic Dentistry.
- Andreotti, A.M., et al., Relationship Between Implant Stability Measurements Obtained by Two Different Devices: A Systematic Review. J Periodontol, 2017. 88(3): 281-288.
- Meredith, N., et al., Resonance frequency measurements of implant stability in vivo. Clin Oral Implants Res, 1997. 8: 226-233.
- Meredith, N., A Review of Nondestructive Test Methods and Their Application to Measure the Stability and Osseointegration of Bone Anchored Endosseous Implants. crit Rev Biomed Eng, 1998. 26(4): 275-291.
- Oh, J.-S. and S.-G. Kim, Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2012. 113(3).
- Zix, J., et al., Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants, 2008. 23(3): 525-30.
- Bilhan, H., et al., The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study. J Oral Implantol, 2015. 41(4): e90-5.
- Pesce, P., et al., Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation. Int J Prosthodont, 2018. 31(2): 171-175.
- Vandeweghe, S., et al., Accuracy of digital impressions of multiple dental implants: an in vitro study. Clin Oral Implants Res, 2017. 28(6): 648-653.
- Papaspyridakos, P., et al., Digital vs Conventional Implant Impressions: A Systematic Review and Meta-Analysis. J Prosthodont, 2020.

